GF SIGNET


515 rotor x515 Rotor-X Paddlewheel Flow Sensors

Simple to install with time-honored reliable performance, Model 515 Rotor-X paddlewheel flow sensors are highly repeatable, rugged sensors that offer exceptional value with little or no maintenance. The output signal of the Model 515 is a sinusoidal frequency capable of driving a self-powered flowmeter (Model 5090). The wide dynamic flow range of 0.3 to 6m/s (1 to 20 ft/s) allows the sensor to measure liquid flow rates in full pipes and can be used in low pressure systems.

Downloads: brochure | manual

 


2536 rotor x2536 Rotor-X Paddlewheel Flow Sensors

Simple to install with time-honored reliable performance, Model 2536 Rotor-X Paddlewheel Flow Sensors are highly repeatable, rugged sensors that offer exceptional value with little or no maintenance. The Model 2536 has a process-ready open collector signal and has a wide dynamic flow range of 0.1 to 6 m/s (0.3 to 20 ft/s). The sensor measures liquid flow rates in full pipes and can be used in low pressure systems.

Downloads: brochure | manual

 

 

 


2537 rotor x2537 Rotor-X Paddlewheel Flowmeter

The Signet 2537 Flow Sensor is the next generation in fluid measurement technology from the inventor of the original paddlewheel flowmeter. This sensor is an enhancement on what’s already an industry standard. It has the added functionality of various output options including flow switch, pulse divider, digital (S3L) or 4 to 20 mA. Additionally, it offers low flow, low power and high resolution options and can be configured on-site directly through the built-in user interface. Installation is simple because the Signet 2537 utilizes the same fittings as the popular Signet 515 and 2536 Paddlewheel Sensors, and fits into pipe sizes ranging from DN 15 to DN 200 (½ to 8 inches). Available in a variety of wetted materials, such as Polypropylene.

Downloads: brochure | manual


3519 flow wet tap3519 Flow Wet-Tap Valve

The Signet 3519 Flow Wet-Tap Valve serves as a unique interface between the installation fitting and the Wet-Tap style Signet 515 or 2536 Rotor-X flow sensor. It provides a fast method of removing the sensor from the pipe under specified operating pressures. The PVC &stainless steel design of the Wet-Tap makes it resistant to corrosion and chemical attack by acids, alkalies, salt, and a number of other harsh chemicals.

The Signet 3519 Wet-Tap Valve mounts directly onto standard Signet installation fittings. The 3519 Wet-Tap consists of a flange and support plate that threads onto the pipe fitting insert, and a PVC ball valve through which an extended length sensor is inserted into the pipe.

Downloads: brochure | manual


525 metalex flow sensor525 Metalex Flow Sensor

The Signet 525 Metalex Flow Sensor offers the added strength of an all stainless steel construction with insertion paddlewheel technology. The result is a highly reliable sensor resistant to extreme pressures and temperatures. The Tungsten Carbide shaft with Fluoroloy B® bearing provide an increased length between maintenance. A comprehensive fitting program allows installation in steel lines with the mini-block for small diameters, and either the mini-tap or saddle for pipes up to DN300 (12 in.). The self-generating signal output allows use with battery operated flow monitor (8150).

Downloads: brochure | manual


turbine flow sensor2100 Turbine Flow Sensor

Engineered specifically for small diameter applications, the Signet 2100 Turbine Flow Sensor provides accurate readings in two flow ranges: 0.1 to 1 gpm and 0.8 to 10 gpm (metric conversion: 0.3 to 3.8 lpm and 3 to 38 lpm). The injection-molded PVDF body and ceramic bearings provide excellent chemical compatibility and long service in dosing and batching applications. Union piping and tubing connections along with removable NEMA 4X electronics allow for easy assembly and field replaceability. The 2100 can be used with 1/4″, 3/8″ or 1/2″ tubing, or 1/2″ piping for installation flexibility. End connections are available in PVDF for hose barbs, flare ends, fusion socket or IR/butt fusion, and in PVC for socket or NPT thread.

Downloads: brochure | manual


brass paddlewheel2517 Brass Paddlewheel Flow Sensor

The Signet 2517 Paddlewheel Flow Sensors offer added strength and durability of brass construction for a variety of applications. The wide flow range of 0.5 to 6m/s (1.6 to 20 ft/s) allows the sensor to measure liquid flow rates in full pipes and can be used in low pressure systems. Fluoroloy B bearings and a Tungsten Carbide pin provide exceptional wear resistance. The 2517 brass sensor signal allows for remote totalization when coupled with the 8150 Battery Powered Flow Totalizer. Sensors can be installed in DN 40 to DN 600 (1.5 to 24 in.) pipes using the 1.5 inch NPT (or ISO 7/1-R 1.5) threaded process connection. The sensors are also offered in a hot-tap configuration with a bleed valve for installation in pipes up to DN 900 (36 in.) and allows for servicing without process shutdown.

Downloads: brochure | manual


flow sensor2540 Stainless Steel High Performance Flow Sensor

The Signet 2540 Paddlewheel flow sensor offers the strength and corrosion resistance of stainless steel for liquid applications with low velocity measurements. Unique internal circuitry eliminates the need for magnets in the process fluid, enabling flow measurement of 0.1 to 6 m/s (0.3 to 20 ft/s) while maintaining the advantages of insertion sensor design. Fluoroloy B® bearings and Tungsten Carbide pin provide exceptional wear resistance. The model 2540 offers field replaceable electronics and transient voltage suppression (TVS) to provide greater immunity to large voltage disturbances (ie. lightening) sometimes encountered in field wiring. Sensors can be installed in DN 40 to DN 600 (1½ to 24 in.) pipes using the 1½ inch NPT or ISO 7/1-R 1.5 threaded process connection. The sensors are also offered in a hot-tap configuration with a bleed valve for installation in pipes up to DN 900 (36 inches) and service without process shutdown. Both styles of sensors must be used in full pipes and can be used in low pressure systems.

Downloads: brochure | manual


flow sensor2551 Magmeter Flow Sensor

The Signet 2551 Magmeter is an insertion style magnetic flow sensor that features no moving parts. The patented* sensor design is available in corrosion-resistant materials to provide long-term reliability with minimal maintenance costs. Material options include PP with stainless steel, PVDF with stainless steel, PVDF with Hastelloy-C, or PVDF with Titanium. Utilizing the comprehensive line of Signet installation fittings, sensor alignment and insertion depth is automatic. These versatile, simple-to-install sensors deliver accurate flow measurement over a wide dynamic range in pipe sizes ranging from DN 15 to DN 300 (0.5 to 12 inches), satisfying the requirements of many diverse applications.

Downloads: brochure | manual


flow sensor2552 Metal Magmeter Flow Sensor

The Signet 2552 Metal Magmeter from Georg Fischer features all-stainless steel construction. The PVDF nosepiece and FPM O-rings are the only other wetted materials. The 2552 installs quickly into standard 1¼ in. or 1½ in. pipe outlets, and is adjustable to fit pipes from DN50 to DN2550 (2 to 102 inches). Three sensor lengths allow maximum flexibility to accommodate a variety of hardware configurations, including ball valves for hot-tap installations.

Downloads: brochure | manual

 

 

 

 


flow totalizer8150 Battery Powered Flow Totalizer

The Signet 8150 Battery Operated Flow Totalizer is compatible with the Signet 515, 525 and 2517 flow sensors, and will provide years of dependable operation. The large digital display indicates flow rate and totalized flow volume simultaneously. One of the three totalizers is resettable from the front panel or a remote location, while the second resettable totalizer can only be reset by entering a user-selectable security code. Meanwhile, the third is a permanent non-resettable totalizer. Our intuitive software design and four-button keypad provide for simple operation while setting screen displays and programming the system. Calibration can be easily performed by entering the Auto-Cal feature and entering a value to match an external reference. Screen displays can be modified to suit the user’s needs; along with the flow rate, any of the three totalizers can be selected as the displayed totalizer. Customers can quickly scroll through the totalizers simply by pressing any key on the keypad. A display averaging feature is included for applications where the flow in the pipe fluctuates. For applications where flow stops and starts due to production needs, a no-flow indicator will display the hours of non-flow.

Downloads: brochure | manual


flow transmitter8550 ProcessPro™ Flow Transmitter

The Signet 8550 Flow Transmitter is an advanced solution that converts the signal from all Signet flow sensors into a 4 to 20 mA signal for long distance transmission, and offers the unique feature of dual input and output capability. Co

nfiguration flexibility is maximized with two optional relays for process control, two packaging options for integral/pipe mount or panel installation, and scalability for virtually any flow range or engineering unit. State-of-the-art electronic design ensures long-term reliability, signal stability, and simple user setup and operation.

     Downloads: brochure        Manuals:  8550-1  |  8550-2  |  8550-3


flow monitor5500 ProPoint™ Flow Monitor

The Signet 5500 Flow Monitor is equipped with a scaleable 4 to 20 mA output and two relays programmable for high, low, and pulse operation. Instantaneous flow rate is easy to read on the analog dial, while the backlit LCD is used for calibration, set-up and displaying totalized flow volumes. One of the two totalizers is resettable from the front panel, and can also be reset from a remote location up to 30 m. (100 ft). The other totalizer is non-resettable and is commonly used to tally consumption, or to permanently record industrial effluent volumes. The monitors require 12 to 24 Volts, AC or DC, and can be used with any Signet Flow Sensor with a frequency output. Our intuitive software design and four-button keypad arrangement provide for simple operation, and the NEMA 4X/IP65 integrity of the front panel can be extended to the entire enclosure by using the optional Rear Cover Kit.

Downloads: brochure | manual


flow monitor5075 Totalizing ProPoint™ Flow Monitor

The Signet 5075 Totalizing Flow Monitor displays flow rate on a highly visible analog dial, and uses a backlit LCD for displaying totalized flow volumes. One of the two totalizers is resettable from the front panel, and can also be reset from a remote location up to 30 m (100 ft.). The other totalizer is non-resettable and is commonly used to tally consumption, or to permanently record industrial effluent volumes. The monitors require 12 to 24 Volts, AC or DC, and can be used with any Signet Flow Sensor with a frequency output. Our intuitive software design and four-button keypad arrangement provide for simple operation, and the NEMA 4X/IP65 integrity of the front panel can be extended to the entire enclosure by using the optional Back Cover Kit.

Downloads: brochure | manual


flow monitor5090 Sensor-Powered ProPoint™ Flow Monitor

The Signet 5090 Sensor-Powered Flow Monitor is an economical analog flow rate indicator, with a meter movement powered by the output signal of Signet 515 Rotor-X and 319/515 Wet-Tap Flow Sensors themselves. No additional power source is required. This unique system is suitable for a wide range of flow rates, and is Factory Mutual (FM) approved for intrinsic safety without the need for barriers. The NEMA 4X/IP65 integrity of the front panel can be extended to the entire enclosure with the use of an optional Rear Cover Kit , adding to the independence and reliability of this simple flow measuring system, even in the most demanding industrial environments.

Downloads: brochure | manual


batch controller5600 ProPoint™ Batch Controller

The Signet 5600 Batch Controller is an extremely refined instrument that combines complex control capability with operational simplicity. Select either Simple or Advanced mode to limit feature options to suit your specific batch requirements, and make changes to batch volume quickly and easily. Two relays and one analog output provide the means to increase batch precision while dramatically reducing the possibility of water hammer in a system. Batch progress is displayed on the analog dial, while the backlit LCD is used for calibration, set-up, and to show totalized flow volumes. The controllers require 12 to 24 Volts, AC or DC, and can be used with any Signet Flow Sensor with a frequency output. The intuitive software design and four-button keypad arrangement is user friendly, and the NEMA 4X/IP65 integrity of the front panel can be extended to the entire enclosure by using the optional Rear Cover Kit.

Downloads: brochure | manual


8900 controller8900 Multi-Parameter Controller

The Signet 8900 Multi-Parameter Controller takes the concept of modularity to the extreme. Each 8900 is field commissioned with the users specified combination of inputs, outputs, and relays using simple-to-install modular boards into the base unit. To assemble a controller, there is a choice of two base units offered with a choice of back-lit LCD or vacuum fluorescent display. Then, continue building with a selection of plug-in modules for either two, four, or six input channels which accepts any of the Signet sensors listed below, and/or other manufacturer’s sensors via a 4 to 20mA signal converter (Signet Model 8058). To complete your unit, choose a power module with universal AC line voltage or 12 to 24 VDC.

Downloads: brochure | manual


fittingsFittings

 

Downloads: brochure

 

 


28502850 Conductivity/Resistivity Sensor Electronics and Integral System.

The Signet 2850 Conductivity/Resistivity Sensor Electronics are available in various configurations for maximum installation flexibility. The universal mount version is for pipe, wall, or tank mounting and enables single or dual (digital output only) inputs using any standard Signet conductivity / resistivity sensor. The threaded j-box version can be used with these same Signet sensors for submersible sensor mounting. It is also available as a combined integral system configuration for in-line mounting and includes a conductivity electrode in a choice of 0.01, 0.1, 1.0, 10.0, or 20.0 cm-1 cell constants. The 2850 is ideal for applications with a conductivity range of 0.055 to 400,000 µS or a resistivity range of 100 Megohms to 10kohms.All 2850 units are available with a choice of two outputs, digital (S3L) or 4 to 20 mA. The digital (S3L) output version allows for up to six sensor inputs directly into the Signet 8900 Multi-Parameter Controller. The two-wire 4 to 20 mA output is available with eight 4 to 20 mA output ranges for each electrode cell constant.

Downloads: brochure | manual


sensors2819-2823 Conductivity/Resistivity Sensors

Signet Conductivity/Resistivity Electrodes are designed to provide versatile installation and accurate sensing across a very broad dynamic range. Coupled with Signet-patented measuring circuitry a three decade range with ±2% of reading accuracy is achieved without the need for troublesome sensor platinization. Platinum RTD (PT-1000) properly located within the sensor allows optimal temperature sensing. Standard wiring allows connection without costly “patch cords”.

Downloads: brochure | manual


npt electrodes2839-2842 NPT Conductivity/Resistivity Electrodes

The 2839-2842 Conductivity/ Resistivity Electrodes are available in four cell constants from 0.01 to 10.0, and are suitable for a wide variety of applications from high purity water quality monitoring to demineralizer regeneration. 316SS electrode surface finishes are controlled in a precision bead blasting operation to ensure measurement accuracy and repeatability. The PEEK insulator and process connections are injection over-molded to minimize variance between electrodes. Double threaded connections in either 3/4 in. NPT or ISO 7/1-R 3/4 enable quick and easy installation in submersible or in-line configurations. Transmitter integral mounting kit and J-Boxes are available as accessories.

Downloads: brochure | manual

 

 


cond transmitter8850 ProcessPro Conductivity/Resistivity Transmitter

The Signet 8850 Conductivity/Resistivity Transmitter is designed for broad application and ease of setup and use. The unit can be used for conductance, resistance, or TDS signal transmission and display. Mounting can be accomplished in several options best tailored to your application requirements. Full-microprocessor based electronics allow wide operating range, and long term signal stability due to the elimination of potentiometers, jumpers and dip switches.

Downloads: brochure         Manual: 8850-1  |  8850-2  |  8850-3


5800cr monitor5800CR ProPoint Conductivity/Resistivity Monitor

The Signet 5800CR Conductivity/Resistivity Monitor is equipped with a scaleable 4 to 20 mA output and two programmable relays for simple and convenient process control and monitoring. Temperature is selectable for display in either °C or °F, and compensation is automatic and programmable (meets USP requirements). The monitor requires 12 to 24 Volts, AC or DC, and can be used with the Signet Conductivity Sensors listed below. The four-button keypad arrangement with intuitive software design is user-friendly, and the NEMA 4X/IP65 integrity of the front panel can be extended to the entire enclosure by using the optional Rear Cover Kit.

Downloads: brochure | manual


electrode2754-2757 pH/ORP Electrodes

The Signet 2754-2757 pH and ORP Electrodes feature a unique foul-proof DryLoc® connector with gold-plated contacts designed specifically for use with the Signet 2750 and 2760 Sensor Electronics and preamplifiers. These dependable and highly responsive electrodes feature a large reference chamber volume and intelligent positioning of internal elements that combine to extend the service life. The electrodes are offered with either flat or bulb sensing elements. The flat versions allow sediment and particles to sweep past the measurement surface, minimizing the risks of abrasion, breakage and coating. The bulb versions can be used for general purpose applications and are also offered with a glass or plastic body for use with the 3719 Wet-Tap assembly.

The choice of a PT-1000 or 3KO temperature sensor allows compatibility with all Signet pH/ORP instruments.

The 2754-2757 electrodes are the flagship sensors of the Signet pH/ORP product line. They are all-purpose sensors ideal for a wide range of universal applications.

Downloads: brochure | manual


electrodes2764-2767 Differential DryLoc™ pH/ORP Electrodes

The Signet 2764-2767 Differential pH & ORP electrodes are built with the DryLocT connector a Ryton® body and TeflonT reference junction to handle even the most extreme and harshest of chemical applications. These differential electrodes use the field-proven 3-electrode differential technique: the pH and reference electrodes are measured against a ground electrode, insuring a steady and stable signal. The key feature of the differential design is the reference electrode. The reference element is protected in a glass half-cell embedded in the reference chamber and is protected from compounds that may contain sulfides (H2S) and metals, including lead, mercury, and silver. To ensure a long service life, the reference features a refillable electrolyte chamber and a replaceable equitransferant salt bridge, both easily serviced in the field. The patented porous TeflonT reference junction resists fouling, clogging and chemical attack. The other elements of the design are the solution ground, the pH/ORP electrodes, and the temperature element. The solution ground eliminates noisy measurements by draining electrical current away from the reference electrode. The pH/ORP electrodes are designed with a flat or bulb measurement surface, and a temperature device that is positioned at the tip of the measurement surface, making the temperature response of T95% less than 1 minute. Various temperature devices offered include 3KO, 300O, or PT-1000 RTD. The electrodes are used with the Signet 2750 Sensor Electronics, which provides a blind 4 to 20 mA output or using the digital (S3L) output may be used to connect to the Signet 8900 instrument. The electrodes can also be used with the Model 2760 preamplifier to connect to the Signet 5700, 8750, or other suppliers’ instruments.

Downloads: brochure


2774 electrode2774-2777 Threaded DryLoc™ pH/ORP Electrodes

The Signet 2774 – 2777 pH and ORP Electrodes feature a unique foulproof DryLoc™ connector with goldplated contacts designed specifically for use with the Signet 2750 and 2760 preamplifiers, sensor electronics, and connectors. These dependable and highly responsive electrodes feature a TeflonT double reference junction and a large reference chamber that combine to extend the service-life. Embedded positioning of the temperature element in the pH/ORP sensing tip allows the temperature response to be quick and accurate. The electrodes are offered with either flat or bulb style sensing elements. The flat versions allow sediment and particles to sweep past the measurement surface, minimizing risks of abrasion, breakage and coating. The bulb versions can be used for general purpose applications. Due to the specially designed chambers which keep electrolyte in place, all versions can be mounted at any angle, even inverted.

Downloads: brochure


pre amplifier2720/2721 Pre-Amplifier

Pre-amplification is required to protect the output signal of pH & ORP electrodes from a wide variety of electromagnetic interference common in industrial environments. The Signet 2720 Pre-amplifier is installed locally, at the sensing point, to maximize this protection while allowing cable extensions up to 120 m (400 ft.). Signet’s unique twist-lock design simplifies installation and maintenance by providing for the quick connection and disconnection of electrodes. And the CPVC body is virtually unbreakable for extended service-life in both submersible and in-line applications. If remote pre-amplification is necessary (e.g., tank temperature > 80° C), or if connecting to another manufacturer’s electrode, use the Signet 2721 Remote Pre-amplifier.

Manuals:  2720  |  2721

 

 


sensor electronics2750 and 2760 DryLoc® pH/ORP Sensor Electronics and Preamplifiers

The Signet 2750 and 2760 pH/ORP Sensor Electronics and Preamplifiers, featuring DryLoc® connectors, provide a variety of functions to suit various requirements.
The 2760 is a preamplifier that allows any DryLoc® pH/ORP electrode to work with most Signet instruments. It is also sold as a simple connector for use with other manufacturers’ instruments that do not require a preamplified signal.

The 2750 comes with the same pre-amplified signal as the 2760, but features two different outputs: a two-wire 4 to 20mA loop output, or a digital (S3L) output which allows for longer cable lengths and is compatible with the Signet 8900 Multi-Parameter Controller. The 2750 devices self-configure for pH or ORP operation via automatic recognition of the electrode type. The optional EasyCal feature allows simple push-button calibration and includes an LED indicator for visual feedback.

The DryLoc® electrode connector found on both models quickly forms a robust assembly for submersible and in-line installations. NEMA 4X junction enclosures are integral parts of the 2750 in-line version and are also available as accessories for both Models 2750 (submersible version) and 2760.

Manual: 2750  |  2760


transmitter8750 ProcessPro pH/ORP Transmitter

The Signet 8750 pH/ORP Transmitter is designed for broad application and ease of setup and use. The unit auto-configures for either pH or ORP use when connected to Signet pH or ORP sensors. Multiple mounting options allow for installation best suited to your particular application. The automated “Easy-cal” menu features automatic buffer recognition for mistake proof pH or ORP sensor calibrations. Intuitive software and the four button keypad arrangement make it easy to access important information such as pH or ORP, mV input, temperature, calibration, relay set-up menus and more.

Manual:  8750-1  |  8750-2  |  8750-3


5700 monitor5700 pH/ORP ProPoint Monitor

The Signet 5700 pH/ORP Monitor is a versatile and intelligent instrument that recognizes the type of sensor connected, either Signet pH or ORP Electrode, then automatically sets itself for the corresponding display and functionality. Also, during “Easy Cal” operation, the monitor automatically recognizes standard buffers/test solutions thereby shortening and simplifying routine calibration procedures. Two programmable relays and one scaleable 4 to 20 mA output are included, and the four-button keypad arrangement with intuitive software design is very user-friendly. The monitors require 12 to 24 Volts, AC or DC, and can be used with the Signet 2720 pH/ORP Preamplifier and Sensor system, or with sensors from other manufacturers by using the 2721 Preamplifier. Several useful accessories are available, including the optional Rear Cover Kit used to extend the NEMA 4X/IP65 integrity of the front panel to the entire enclosure.